Acqua purissima e sicura!
ora anche con irradiazione UV
e misurazione del TOC in linea.
Ultrapure water quality - with no reservations!
There are areas in which particularly high demands are placed on the water quality.
In chemical organic or inorganic trace analysis, for example, for TOC measurements and
instrumental methods such as HPLC, ICP-MS and IC.And the demands are even higher in the life sciences. Freedom from endotoxines and
nucleases is a necessity when preparing, or working with, tissue and cell culture media,
PCR, DNA, or monoclonal antibodies.The Standard, UF, UV and UV/UF versions of GenPure have already convincingly
demonstrated the benefits of the new system control and the high-precision, USP-complying
conductivity measurement with temperature compensation that can be switched on or off.
Technical intelligence for reliable processes!
TKA Measurement methods. Highest accuracy and reliability!
Exact dispensing
Conductivity measurement
Temperature measurement
Online TOC measurement
Monitoring of the intensity of the UV-radiation
TKA xCAD: extended Control And Dispenser unit
For flexible operation in the lab! Leaves more elbow-room on the lab bench!
With a footprint about the size of an A 4 portrait, GenPure can be stood on the lab bench or, if
preferable, it can be hung on a wall (without the need for extra mounting material).The space-saving under bench version can have up to three flexible control/dispenser units fitted
to it for use at up to 3 m distance from it. Can be stood on a bench or be even more space-savingly
wall mounted
![]() |
![]() |
Technical details
| TKA GenPure |
TKA GenPure UF |
TKA GenPure UV |
TKA GenPure UF/UV | |
| Flow rate, up to: | up to 2 l/min | up to 2 l/min | up to 2 l/min | up to 2 l/min |
| Operating pressure in bar, min/max: | 2 – 6 bar | 2 – 6 bar | 2 – 6 bar | 2 – 6 bar |
| Conductivity: Resistance at 25 °C: TOC value: Bacterial content in KbE/ml: Particles: Endotoxines in EU/ml: |
0.055 µS/cm 18.2 MΩxcm 5 – 10 ppb <1 <1 – |
0.055 µS/cm 18.2 MΩxcm 5 – 10 ppb <1 <1 0,001 |
0.055 µS/cm 18.2 MΩxcm 1 – 5 ppb <1 <1 – |
0.055 µS/cm 18.2 MΩxcm 1 – 5 ppb <1 <1 0,001 |
| Electrical requirements: | 230 V / 50Hz | 230 V / 50Hz | 230 V / 50Hz | 230 V / 50Hz |
| Power consumption: | 0.1 kW | 0.1 kW | 0.1 kW | 0.1 kW |
| Feedwater connector: | R 3/4" | R 3/4" | R 3/4" | R 3/4" |
| Dimensions B x T x H in mm: | 372 x 330 x 615 | 372 x 330 x 615 | 372 x 330 x 615 | 372 x 330 x 615 |
| Weight: | 22 kg | 23 kg | 23 kg | 23 kg |
| Article no. | 08.2202 | 08.2203 | 08.2205 | 08.2204 |
| TKA GenPure UV-TOC | TKA GenPure UV-TOC/UF | |
| Flow rate: | up to 2 l/min | up to 2 l/min |
| Operating pressure in bar, min/max: | 0.1 – 6 bar | 0.1 – 6 bar |
| Conductivity: Resistance at 25 °C: TOC value: Bacterial content in KbE/ml: Particles: Endotoxines in EU/ml: |
0.055 µS/cm 18.2 MΩxcm 1 – 5 ppb <1 <1 – |
0.055 µS/cm 18.2 MΩxcm 1 – 5 ppb <1 <1 0,001 |
| Electrical requirements: | 230 V / 50 Hz | 230 V / 50 Hz |
| Power consumption: | 0.1 kW | 0.1 kW |
| Feedwater connector: | R 3/4" | R 3/4" |
| Dimensions B x T x H in mm: | 372 x 330 x 615 | 372 x 330 x 615 |
| Weight: | 24 kg | 25 kg |
| Article no. | 08.2206 | 08.2207 |
GenPure systems incl. xCAD Dispenser
| TKA GenPure |
TKA GenPure UF |
TKA GenPure UV-TOC |
TKA GenPure UV-TOC/UF | |
|
with dispenser |
with dispenser |
with dispenser |
with dispenser | |
| Cat. no.: | 08.2222 | 08.2213 | 08.2216 | 08.2217 |
|
with dispenser |
with dispenser |
with dispenser |
with dispenser | |